DPI-Score assessed protein-interface geometry from atomic coordinates and reported 87.53% validation accuracy, then flagged errors missed by density-based scores across 29,120 interfaces; it complements rather than replaces existing structure checks.
The story
Cryogenic electron microscopy can resolve large protein assemblies, but building atomic models becomes difficult where resolution is poorer than about 3 ångströms or varies across the image. Many existing checks focus on how a model fits the density map rather than whether two proteins meet plausibly at an interface.
DPI-Score uses the raw coordinates of atoms at an interface without hand-designed features. The authors report 87.53 percent validation accuracy and applied the model to 29,120 interfaces from 6,011 fitted entries in the Electron Microscopy Data Bank with resolutions worse than 3 ångströms.
The method found some interface problems that density-based scores did not flag. It is intended as a complementary check, not a replacement for density fit, geometry review, expert judgment, or experimental refinement; a learned score can still miss errors or flag acceptable structures.
Original source: Nature Communications
Published by Nature Communications on November 14, 2026. Wonder Daily presents the information in its consistent reader format and credits the original publisher.